Background
Gender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological distress and health-related quality of life (HQOL), we examined the relationship between gender and patient-reported outcomes in patients with an ICD in the first year after ICD implantation.
Methods
Consecutive patients (N = 300) receiving an ICD between September 2007 and February 2010 at Medisch Spectrum Twente hospital, the Netherlands, completed several questionnaires to assess psychological distress and HQOL prior to ICD implantation and at 2 months, 5 months, 8 months, and 12 months postimplantation.
Results
Correcting for clinical confounders (e.g., left ventricular ejection fraction, ICD indication, comorbidities, ICD shocks), women reported higher levels of anxiety (P = 0.021) and shock-related anxiety (P = 0.047) than men in the course of a year. On most HQOL subscales, no gender differences were found, except for subscale Physical functioning, where women reported higher levels of improvement compared to men (P = 0.008). Gender was independently associated with poorer device-related acceptance, but only on the Florida Patient Acceptance Scale domain Body image concerns (P = 0.043), with women expressing higher levels of concerns about their body image compared to men.
Conclusions
Women report higher levels of general and shock-related anxiety, and higher levels of body image concerns than men. Women showed more improvement in physical functioning. Screening patients before and after ICD implantation for general and shock anxiety may help determine patients who could benefit from psychological counseling.
Original languageEnglish
Pages (from-to)843-852
JournalPACE. Pacing and Clinical Electrophysiology
Volume37
Issue number7
DOIs
Publication statusPublished - 2014

Keywords

  • ICD
  • gender
  • quality of life
  • anxiety
  • depression
  • psychological distress

Cite this

Starrenburg, A., Pedersen, S., van den Broek, K. C., Kraaier, K., Scholten, M., & Van der Palen, J. (2014). Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant. PACE. Pacing and Clinical Electrophysiology, 37(7), 843-852. https://doi.org/10.1111/pace.12357
Starrenburg, Annemieke ; Pedersen, Susanne ; van den Broek, K.C. ; Kraaier, Karin ; Scholten, Marcoen ; Van der Palen, Job. / Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant. In: PACE. Pacing and Clinical Electrophysiology. 2014 ; Vol. 37, No. 7. pp. 843-852.
@article{7f84ae4495ab438bbf1143e55e394193,
title = "Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant",
abstract = "BackgroundGender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological distress and health-related quality of life (HQOL), we examined the relationship between gender and patient-reported outcomes in patients with an ICD in the first year after ICD implantation.MethodsConsecutive patients (N = 300) receiving an ICD between September 2007 and February 2010 at Medisch Spectrum Twente hospital, the Netherlands, completed several questionnaires to assess psychological distress and HQOL prior to ICD implantation and at 2 months, 5 months, 8 months, and 12 months postimplantation.ResultsCorrecting for clinical confounders (e.g., left ventricular ejection fraction, ICD indication, comorbidities, ICD shocks), women reported higher levels of anxiety (P = 0.021) and shock-related anxiety (P = 0.047) than men in the course of a year. On most HQOL subscales, no gender differences were found, except for subscale Physical functioning, where women reported higher levels of improvement compared to men (P = 0.008). Gender was independently associated with poorer device-related acceptance, but only on the Florida Patient Acceptance Scale domain Body image concerns (P = 0.043), with women expressing higher levels of concerns about their body image compared to men.ConclusionsWomen report higher levels of general and shock-related anxiety, and higher levels of body image concerns than men. Women showed more improvement in physical functioning. Screening patients before and after ICD implantation for general and shock anxiety may help determine patients who could benefit from psychological counseling.",
keywords = "ICD, gender, quality of life, anxiety, depression, psychological distress",
author = "Annemieke Starrenburg and Susanne Pedersen and {van den Broek}, K.C. and Karin Kraaier and Marcoen Scholten and {Van der Palen}, Job",
year = "2014",
doi = "10.1111/pace.12357",
language = "English",
volume = "37",
pages = "843--852",
journal = "PACE. Pacing and Clinical Electrophysiology",
issn = "0147-8389",
publisher = "Wiley-Blackwell",
number = "7",

}

Starrenburg, A, Pedersen, S, van den Broek, KC, Kraaier, K, Scholten, M & Van der Palen, J 2014, 'Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant', PACE. Pacing and Clinical Electrophysiology, vol. 37, no. 7, pp. 843-852. https://doi.org/10.1111/pace.12357

Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant. / Starrenburg, Annemieke; Pedersen, Susanne; van den Broek, K.C.; Kraaier, Karin; Scholten, Marcoen; Van der Palen, Job.

In: PACE. Pacing and Clinical Electrophysiology, Vol. 37, No. 7, 2014, p. 843-852.

Research output: Contribution to journalArticleScientificpeer-review

TY - JOUR

T1 - Gender differences in psychological distress and quality of life in patients with an ICD 1-year postimplant

AU - Starrenburg, Annemieke

AU - Pedersen, Susanne

AU - van den Broek, K.C.

AU - Kraaier, Karin

AU - Scholten, Marcoen

AU - Van der Palen, Job

PY - 2014

Y1 - 2014

N2 - BackgroundGender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological distress and health-related quality of life (HQOL), we examined the relationship between gender and patient-reported outcomes in patients with an ICD in the first year after ICD implantation.MethodsConsecutive patients (N = 300) receiving an ICD between September 2007 and February 2010 at Medisch Spectrum Twente hospital, the Netherlands, completed several questionnaires to assess psychological distress and HQOL prior to ICD implantation and at 2 months, 5 months, 8 months, and 12 months postimplantation.ResultsCorrecting for clinical confounders (e.g., left ventricular ejection fraction, ICD indication, comorbidities, ICD shocks), women reported higher levels of anxiety (P = 0.021) and shock-related anxiety (P = 0.047) than men in the course of a year. On most HQOL subscales, no gender differences were found, except for subscale Physical functioning, where women reported higher levels of improvement compared to men (P = 0.008). Gender was independently associated with poorer device-related acceptance, but only on the Florida Patient Acceptance Scale domain Body image concerns (P = 0.043), with women expressing higher levels of concerns about their body image compared to men.ConclusionsWomen report higher levels of general and shock-related anxiety, and higher levels of body image concerns than men. Women showed more improvement in physical functioning. Screening patients before and after ICD implantation for general and shock anxiety may help determine patients who could benefit from psychological counseling.

AB - BackgroundGender differences in patient-reported outcomes in patients with an implantable cardioverter defibrillator (ICD) have been researched, but findings are inconclusive and mostly based on cross-sectional study designs. To gain a better insight into potential determinants of psychological distress and health-related quality of life (HQOL), we examined the relationship between gender and patient-reported outcomes in patients with an ICD in the first year after ICD implantation.MethodsConsecutive patients (N = 300) receiving an ICD between September 2007 and February 2010 at Medisch Spectrum Twente hospital, the Netherlands, completed several questionnaires to assess psychological distress and HQOL prior to ICD implantation and at 2 months, 5 months, 8 months, and 12 months postimplantation.ResultsCorrecting for clinical confounders (e.g., left ventricular ejection fraction, ICD indication, comorbidities, ICD shocks), women reported higher levels of anxiety (P = 0.021) and shock-related anxiety (P = 0.047) than men in the course of a year. On most HQOL subscales, no gender differences were found, except for subscale Physical functioning, where women reported higher levels of improvement compared to men (P = 0.008). Gender was independently associated with poorer device-related acceptance, but only on the Florida Patient Acceptance Scale domain Body image concerns (P = 0.043), with women expressing higher levels of concerns about their body image compared to men.ConclusionsWomen report higher levels of general and shock-related anxiety, and higher levels of body image concerns than men. Women showed more improvement in physical functioning. Screening patients before and after ICD implantation for general and shock anxiety may help determine patients who could benefit from psychological counseling.

KW - ICD

KW - gender

KW - quality of life

KW - anxiety

KW - depression

KW - psychological distress

U2 - 10.1111/pace.12357

DO - 10.1111/pace.12357

M3 - Article

VL - 37

SP - 843

EP - 852

JO - PACE. Pacing and Clinical Electrophysiology

JF - PACE. Pacing and Clinical Electrophysiology

SN - 0147-8389

IS - 7

ER -